BEP701 DUAL OPERATION 12volt VSR AND EMERGENCY PARALLEL - RATING 275
Description
Incorporates the same auto charging functionality as the BEP VSR
- Dual battery sensing
- Remote emergency parallel function: the 701-MDVS and 720-MDVS can be
operated through a momentary button on the dash which will parallel the
batteries for a preset time of 10 minutes. Once this 10 minutes has passed,
if the voltage is up high enough for the voltage sensitive switch to operate, it
will stay engaged. If not, it will disengage.
- Engine run sensing: VSS will engage when the voltage on either the start or
house battery reaches 13.7 volts. If the combined battery voltage drops
below 13.0 volts and the engine is not running, after 5 seconds the contacts
will open and stay open until the start or house battery voltage exceeds 13.7
volts. If the combined battery voltage drops below 12.2 volts and the engine
is running, after 5 minutes the contacts will open and stay open until the
start or house battery voltage exceeds 13.7 volts. If voltage drops below 13
volts and stays above12.2 volts on either start or house battery while engine
is running, the VSS will stay engaged.
- Manual override option
- The advantage of using a high current VSS is that it will cover your dual
battery charging requirements and emergency parallel operation in one unit.